Emergency Ventilator

Emergency Ventilator
Product Detailed
emergency Ventilator Used for: first aid, ambulance and patients hospital transport ,C, A/C, SIMV, SIGH, CPAP

emergency Ventilator

Used for First-Aid, Ambulance, Emergency situation and patients transport in hospital, it can be used for pediatric and adult patients. A button operation, it is simple to use with digital control and  precise parameters, and contains special self test function to ensure the patient’s safe. It consists of ventilators, 2L Aluminum Oxygen Cylinder, Breathe Circuit, Carrying Package, Special Bracket for ambulance and pressure reducing valve for large oxygen cylinder, etc. 1. Specifications

Kinds of mode C,  A/C,  SIMV,  SIGH,  CPAP,  PEEP
ParametersRangeRemark
Tidal Volume50~2000 mlDigital Precise Adjustable
Respiratory Rate1~100 bpmDigital Precise Adjustable
O2%45~100%Digital Precise Adjustable
Trigger Level-20~0 hpaDigital Precise Adjustable
Peak Pressure0~60 hPaDigital Precise Adjustable
PEEP0~20 hPaDigital Precise Adjustable
SIGH1~10 times per 100 breathDigital Precise Adjustable

2. Monitor

DisplayRange
Large LCD Screen Data DisplayTidal Volume, O2%, Sigh, Respiratory Rate, Flow,Pressure (Synchronized Trigger, Peak Airway, CPAP, PEEP )
Large LCD Screen Curve DisplayAirway Pressure Time Waveform Display
Alarm Data DisplayHigh/Low Airway Pressure Alarm, Lack of Gas/Power Alarm,Parameter Error
Other DisplayLock, Charge Indicator, Inspiratory/Expiratory Situation,DC/AC Power Supply

3.Self Test, Alarm and Protection. Special Self Test

JOGGER Portable ventilator complies with the latest National standards,such as YY0600.3-2007,ISO9001,ISO13485,CHINA FDA,etc
Circuit Connect PromptRemind the operator to connect the breath circuit correctly to access the using state
Sound Alarm TestTest sound alarm, to guarantee the reliability using
Gas Pressure TestTest gas pressure, remind operator to ensure the gas pressure supply
Internal Battery Capacity TestTest the capacity of the internal battery
Circuit Leakage TestTest Circuit Leakage, to lest circuit drop off or leak and unexpected situation to happen
 Alarm

JOGGER portable ventilator contains perfect alarm function and response the machine and patient condition timely and effectively.
High Airway PressureLow Airway Pressure
Low Battery Voltage AlarmLow Gas Pressure
Parameter ErrorSilence
High Frequency Alarm

Emergency Ventilator



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.